Release Notes

Issue 2: BITS088419
Description: Feature Lifecycle Log Replication on OS Log shows one-hour difference in the EventTimeStamp displayed in the
OS log, when daylight saving is applied.
Issue 3: JIT-102480
Description: When iDRAC Service Module 3.3.0 is installed on RHEL 6.10 operating system with SELinux enabled in either of
Permissive or Enforcing modes, AVC denial logs (AVC denial is noticed with iptables) are observed in /var/log/audit/
audit.log while the following features are enabled or disabled:
1. iDRAC Access via Host OS.
2. Host SNMP Alerts.
Workaround: iDRAC Service Module 3.3.0 does not support explicit SELinux policies. No action is expected from the user. There
is no functionality impact to iSM features due to this. Future releases of iSM shall address the AVC denials.
Issue 4: JIT-106937
Description:If dependent packages for iSM are not present on Ubuntu OS, then installation through OS DUP installs iSM in
install+unpacked state. You can verify this using the below command:
#dpkg -s dcism
Package: dcism
Status: install ok unpacked
Workaround:To fix this issue, run the command apt-get install -f. This will install dependent packages.
Known Issues, Limitations, and Workaround on VMware ESXi Operating
Systems
Issue 1
Description: After performing an iDRAC Hard Reset operation on certain VMware ESXi operating systems, the IPMI driver
(ipmi_si_drv) may become unresponsive because of an existing issue in the IPMI driver. If the IPMI driver becomes
unresponsive, reload the IPMI driver (ipmi_si_drv).
The issue is observed on all iDRAC Service Module supported ESXi versions.
To reload the ipmi_si_drv:
/etc/init.d/sfcbd-watchdog stop
esxcfg-module -u ipmi_si_drv => unload ipmi_si_drv
esxcfg-module ipmi_si_drv => load ipmi_si_drv
/etc/init.d/sfcbd-watchdog start Alternatively, the administrator can also restart the Host OS to resolve the
issue.
Issue 2
Description: The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
Issue 3
Description: When Local Racadm set is disabled through iDRAC interfaces:
The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
if OS to iDRAC Pass-through in the USB NIC mode is already configured, Watchdog feature does not work resulting in
ASR000 event.