Release Notes

The issue is observed on all iDRAC Service Module supported ESXi versions.
To reload the ipmi_si_drv:
/etc/init.d/sfcbd-watchdog stop
esxcfg-module -u ipmi_si_drv => unload ipmi_si_drv
esxcfg-module ipmi_si_drv => load ipmi_si_drv
/etc/init.d/sfcbd-watchdog start — Alternatively, the administrator can also restart the Host OS to resolve the issue.
Issue 2
Description: The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
Issue 3
Description: When Local Racadm set is disabled through iDRAC interfaces:
— The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
— if OS to iDRAC Pass-through in the USB NIC mode is already configured, Watchdog feature does not work resulting in ASR000 event.
iDRAC Service Module functionality is restored when Local Racadm set is enabled.
Issue 4
Description: EventID for Lifecycle Controller Logs replicated to OS log will be 0 for some of the past events.
Issue 5
Description: TrapID for In-band SNMP Traps will be 0 for some of the past traps.
Issue 6 (JIT-91716, JIT-90475)
Description: WSMan commands for remote iDRAC Hard Reset and remote Enabling or Disabling of InBandSNMPTraps features are not
functional on VMware ESXi 6.7.
Workaround: Stop and start WBEM in ESXi 6.7 using the following commands:
1. esxcli system wbem set –e 0
2. esxcli system wbem set –e 1
Issue 7 (JIT-87572)
Description: When iDRAC Hard Reset is disabled in iDRAC and user performs iDRACHardReset from the Hypervisor operating systems
like VMware ESXi, the result indicates success although iDRAC is not reset.
Issue 8 (JIT-101652, JIT-102735, JIT-103063)
Description: While upgrading iDRAC Service Module ESXi Live VIB package through VMware Update Manager (VUM), the host OS
enters maintenance mode and then reboots..
4