Release Notes
Table Of Contents
● On Dell’s 12th generation of PowerEdge servers with iDRAC firmware version 1.57.57 or earlier, Windows Management
Instrumentation (WMI) feature is not active by default. The WMI feature is automatically activated when iDRAC firmware
version 2.10.10.10 or later is installed (BITS113354).
● On Windows operating system, a feature that is enabled using the installer and disabled using any interface other than the
installer, can only be enabled using the same interface or the installer in GUI mode (BITS180635).
● If iDRAC Service Module 2.0 or later is used with an iDRAC firmware version prior to 2.10.10.10, the WMI interface may stop
responding. It is recommended to upgrade to the latest iDRAC firmware or reset the iDRAC (BITS178203).
● When iDRAC Service Module 2.3 is used for WMI queries through WinRM, additional properties with null value may be
observed. This can be ignored.
● Feature Lifecycle Log Replication on OS Log shows one-hour difference in the EventTimeStamp displayed in OS log, when
daylight saving is applied.
● On Linux Operating Systems, when iDRAC Service Module 2.3.0 and iDRAC Service Module 2.3.0.1 patch are installed,
then to uninstall iDRAC Service Module completely, the iDRAC Service Module 2.3.0.1 patch has to be uninstalled before
uninstalling iDRAC Service Module 2.3.0.
● The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
● When Local RACADM set is disabled through iDRAC interfaces,
○ The iDRAC Service Module will fail to configure the OS to iDRAC Pass-through in the USB NIC mode.
○ If OS to iDRAC Pass-through in the USB NIC mode is already configured, Watchdog feature does not work resulting in
ASR000 event.
iDRAC Service Module functionality is restored when "Local racadm set" is enabled.
● When you use iDRAC Service Module 2.3 for WMI queries over winrm, additional properties with null value is observed. This
does not affect the functionality and it can be ignored.
● If iDRAC Service Module 2.3.0 is installed on a Linux OS with the iDRAC Access via Host OS feature enabled, you have to to
remove the rules of the previous port when upgrading from 2.3.0 to 2.4.0.
● When the iDRAC's USB NIC is not functioning, the iDrac Service Module installer is completing the installation and starting
the iDRAC Service Module process without any notification about the failure to start the communication with the iDRAC.
This issue is observed during iDRAC Service Module is installed using setup.sh command the iDRAC.
4