White Papers

34 Update 1803 for Cloud Platform System (CPS) Standard
-Fixes an issue where a random corner case firmware FMU fault can lead to controller hangs for
approximately 15 seconds. Search controller logs for the string "fushionMUErrorIsr: FMU Error Sttus
00040000."
-Fixes an issue where SATA drives could randomly return 04/44/00 check condition in a VSAN
environment. Search the controller log for the string "Sense: 4/44/00". For example: "07/24/17
11:00:55: C0:EVT#8446014-07/24/17 11:00:55: 113=Unexpected sense: PD 02(e0x20/s2) Path
500056b3fafedac2, CDB: 9e 10 00 00 00 00 00 00 00 00 00 00 00 20 00 00, Sense: 4/44/00"
-Fixes an issue where you can see false multiple SRAM correctable errors that could result in
performance problems or even in a server crash. Search tty log for the string "SRAM errAddr" or
"Correctable err, continuing...". For example: "C0:SRAM errAddr c0023010 errAttrib 00000003"
followed by "C0:Correctable err, continuing..."
-Fixes an issue where a random RSOD could occur during boot only if there are multiple PERC
controllers in the config.
-Fixes an issue where VD deletion and VD creation events are not seen in iDRAC LC log.
-Fixes an issue where sometimes controller fails to unlock and import multiple secure foreign
configurations only if foreign VDs have different secured pass phrases.
o Enhancements
-None
Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.4.0006 Fixes
& Enhancements
o Fixes
-Changes default value of drive cache for 6 Gbps SATA drive to disabled. This is to align with the industry
for SATA drives. This may result in a performance degradation especially in non-Raid mode. You must
perform an AC reboot to see existing configurations change.
-Fixes an issue where a specific firmware FMU fault can lead to controller hangs for approximately 15
seconds. Search controller logs for the string "fusionMUErrorIsr: FMU Error Status 00040000".
-Fixes an issue where SATA drives could randomly return 04/44/00 check condition in a VSAN
environment. Search the controller log for the string "Sense: 4/44/00". For example: "07/24/17 11:00:55:
C0:EVT#8446014-07/24/17 11:00:55: 113=Unexpected sense: PD 02(e0x20/s2) Path 500056b3fafedac2,
CDB: 9e 10 00 00 00 00 00 00 00 00 00 00 00 20 00 00, Sense: 4/44/00"
-Fixes an issue where you can see false multiple SRAM correctable errors that could result in
performance problems or even in a server crash. Search tty log for the string "SRAM errAddr" or
"Correctable err, continuing...". For example: "C0:SRAM errAddr c0023010 errAttrib 00000003" followed
by "C0:Correctable err, continuing..."
-Fixes an issue where external enclosures sometimes lose time sync.
-Fixes an issue where a random RSOD could occur during boot only if there are multiple PERC
controllers in the configuration.
-Fixes an issue where the battery could inadvertently change to WT during a transparent learn cycle.
-Fixes an issue where VD deletion and VD creation events are not seen in iDRAC LC log.
-Fixes an issue where sometimes controller fails to unlock and import multiple secure foreign
configurations only if foreign VDs have different secured pass phrases.
o Enhancements
-None
Dell HBA330 Mini firmware version 15.17.08.01 Fixes & Enhancements
o Fixes:
Miscellaneous SATA fixes including::
- SMART Passthrough Commands might fail in some circumstances
- Passthrough commands issued PIO Mode might receive incorrect status values
- Inquiry to page 0xB0 returned truncated data
- Inquiry to VPD page 0x89 returned extra, invalid data
- Unmap command translation for SATA drives might fail if Number of Logical Blocks or Parameter List Length
was set to zero