Administrator Guide

Figure 76. Troubleshoot options
The server restarts and completes factory rst-boot automation.
CAUTION: After completing this factory reset process, wait for at least 30 minutes before proceeding to the next step.
14 From the iDRAC Virtual Console, select Power > Graceful Shutdown.
Figure 77. iDRAC Graceful Shutdown
The storage hosts power o. Later in the factory reset process, you follow the power-on procedures for Dell Hybrid Cloud System for
Microsoft, as described in Starting up the stamp.
NOTE
: Upon completion of the factory reset process, manually power o the (MD14xx) JBODs that are connected to
the R730s.
Resetting the compute cluster (<
Prex
>CCL)
1 Open iDRAC Consoles for each physical host. Connect the Field Engineer (FE) laptop. It is connected to Port TE 1/40 on one of the
Top of Rack switches. Congure the laptop with the IP in the Solution Integration Document (SID).
2 Log on to the server with an account that has local Administrator permissions, for example, as a member of the <
Prex
>-Diags-
Admins group.
3 Open an elevated command prompt, and run the following command:
reagentc /boottore
4 If you receive a message saying REAGENTC.EXE: Operations successful, continue to the next step.
148
Appendix B: Performing a factory reset