Administrator Guide
Figure 40. Add initiator ID
3 Click Next, and follow the wizard to complete the VHD setup.
Step 2 Add the iSCSI disk to the DPM server as a staging area
1 Log on to the DPM server and start the ISCSI initiator. In Server Manager, on the Tools menu, click iSCSI Initiator. When prompted to
start the service, click Yes.
The iSCSI Initiator Properties dialog box opens.
2 In the Target box, enter the name or IP address of the source server (that is, the server on which you created the iSCSI disk), click
Quick Connect, and then click Done.
The target should show as Connected.
Figure 41. Target connected
3 Open Disk Management, initialize the newly added disk, and create a volume.
4 Change the staging area to point to this disk.
a In the DPM Administrator console, open the Management workspace.
84
Operations