Dell Storage support policy statement
10 Dell EMC Storage Compatibility Matrix for SC, PS, and FS Series Arrays | DSCM
• A Dell PS Series SAN infrastructure introducing or adding a Dell SC Series array solution to the
existing PS Series SAN
Note: Any other array coexistence solution is not supported at the time of the publish date of this document.
This scenario implies that certain criteria will be assumed and only these configurations will receive Level 1
support:
• iSCSI only
• A single IP subnet
• PS Series Host Integration Tools may (or may not) be installed on individual hosts where supported
To determine the support level of the coexistence solution, the following rules apply:
• Level 1 support is provided, assuming that for each array solution (PS Series and SC Series), all of
the components used (operating systems, Adapters, and switches) are listed in the matrices included
in this document, and that the support policy statement described earlier in this document is applied
to each solution
• Level 2 support is provided if any included component qualifies for Level 2 support for either of the
array solutions
• Level 3 support is provided for any other solutions
2.6 FS Series additional support statement
The FS Series of products are NAS appliances that work with the various Dell Storage PS Series and SC
Series products. All FS Series products are tested for interoperability with their respective back-end storage
array products, and Dell will support any and all issues arising in or between these products while the
products are under warranty and/or under an active ProSupport or Copilot support contract for both products.
The following sections describe general support policies for the FS Series, particularly as they relate to the
results published in this document. There are additional environmental and cabling considerations that should
be taken into account when building a storage solution that includes FS Series NAS appliances.
Please consult other FS Series documentation or contact your Dell account representative to ensure that all
the relevant factors have been taken into consideration.
2.6.1 Switch support policy
Dell tests switches for two of the three networks associated with an FS Series NAS cluster, namely the back-
end iSCSI or Fibre Channel (FC) network situated between the NAS controllers and the PS Series or SC
Series storage arrays. The FS76x0 Series NAS appliances connect to the PS Series SAN arrays using the
industry-standard iSCSI protocol, while the FS8000 Series NAS appliances connect to the SC Series SAN
arrays using either iSCSI or Fibre Channel. For proper configuration, at least one switch is required (a
minimum of two switches is recommended) to interconnect these products. Direct connection of any FS
Series NAS appliances and the respective arrays is not supported.
The three levels of support described previously are applicable to the FS Series switches listed in this matrix
for back-end network configuration.