White Papers
40 PowerEdge 14th generation (14G) acoustical performance and dependencies | Document ID | version (optional)
Acoustical performance of M640
Configuration
Minimum
Typical - 1
Typical - 2
Host Chassis
M1000e
M1000e
VRTX
CPU Type
Intel Xeon Gold 5115
Intel Xeon Gold 5118
Intel Xeon Gold 5118
CPU TDP
85W
105 W
105 W
CPU Quantity per blade
1
2
2
Memory Type
4GB, 2667MHz, DDR4
8GB, 2667MHz, DDR4
8GB, 2667MHz, DDR4
DIMM Quantity per blade
4
12
4
Backplane Type
2.5” x 2
2.5” x 2
2.5” x 2
HDD Type
7.2K RPM SATA
10K RPM SAS
10K RPM SAS
HDD Quantity per host chassis
1
2
2
PSU Type
2700 W
2700 W
1100 W
PSU Quantity per host chassis
3
3
2
PERC
None
H330 Mini
H330 Mini
PCI
4x 1GbE NDC
4x 1GbE NDC
4x 1GbE NDC
Blade q’ty per host chassis
8
8
3
Acoustical Performance: Idle/Operating @ 23 °C Ambient
LwA-UL
2
(Bels)
Idle
1
7.1
7.3
5.4
Operating
1
7.2
7.6
5.8
LpA
3
(dBA)
Idle
1
54
56
37
Operating
1
56
60
42
Prominent tones
4
No prominent tones
4
in Idle
1
and Operating
1
Acoustical Performance: Max. Loading @ 35 °C Ambient
LwA-UL
2
(Bels)
8.3
9.6
7.5
LpA
3
(dBA)
67
79
57
Footnotes:
Idle means the state in which the product is doing nothing but running OS, and values for Operating are the maximum of acoustical output for
active HDDs or active processors.
LwA-UL is the upper limit sound power levels (LwA) calculated per section 4.4.1 of ISO 9296 (1988) with data collected in accordance with
ISO 7779 (2010) from a single sample with a total 0.3 bel production deviation applied.
LpA is the average bystander position A-weighted sound pressure level calculated per section 4.3 of ISO 9296 (1988) and measured in
accordance with ISO 7779 (2010).
M1000e is installed in a Dell 42-U rack such that the bottom of the Enclosure is at 25-cm from the floor of the chamber
VRTX is placed on the floor, and adjacent to the standard test table with a distance of 7.5-cm from the vertical plane formed by the edge of
the top of the table (with reference to Figure C.4.c of ECMA-75 [2012] Section C.15.2.)
Prominent tone: Criteria of D.6 and D.11 of ECMA-74 12th ed. (2012) are followed to determine if discrete tones are prominent.
M1000e is installed in a Dell 42-U rack such that the bottom of the Enclosure is at 75 +/- 3-cm from the floor of the chamber. The acoustic
transducers are at front and rear bystander positions.
VRTX is placed on the floor, and adjacent to the standard test table with a distance of 7.5-cm from the vertical plane formed by the edge of
the top of the table (with reference to Figure C.4.c of ECMA-75 [2012] Section C.15.2.) The acoustic transducers are at front and rear
bystander positions.