8 PowerEdge 14th generation (14G) acoustical performance and dependencies | Document ID | version (optional)
Acoustical performance of R240
Configuration
Minimum
Typical-1
Typical-2
Feature Rich
CPU Type
Intel E-2124
Intel E-2124
Intel E-2124
Intel E-2126G
CPU TDP
71 W
71 W
71 W
80 W
CPU Quantity
1
1
1
1
Memory Type
8GB UDIMM
8GB UDIMM
16GB UDIMM
16GB UDIMM
DIMM Quantity
1
1
2
4
Backplane Type
2x 3.5" Cabled
4x 3.5" Cabled
4X 3.5" Hot-plug
4X 3.5" Hot-plug
Fan Quantity
2 x 4028
3 x 4028
4 x 4028
4 x 4028
HDD Type
3.5" SATA 1-TB
3.5" SATA 1-TB
3.5" SATA 2-TB
3.5" SATA 2-TB
HDD Quantity
1
2
2
4
PSU Type
250 W
250 W
250 W
250 W
PSU Quantity
1
1
1
1
PCI 1
PERC H330
PERC H330
PCI 2
-
PCI 3
-
Acoustical Performance: Idle/ Operating @ 25 °C Ambient
LwA-UL
2
(Bels)
Idle
1
4.6
4.6
5.1
5.2
Operating
1
4.7
4.8
5.1
5.2
LpA
3
(dBA)
Idle
1
39
39
43
43
Operating
1
40
40
43
43
Prominent tones
4
No prominent tones
4
in Idle
1
and Operating
1
Acoustical Performance: Idle @ 28 °C Ambient
LwA-UL
2
(Bels)
5.5
5.7
6.1
6.1
LpA
3
(dBA)
38
41
45
44
Acoustical Performance: Max. Loading @ 35 °C Ambient
LwA-UL
2
(Bels)
7.7
7.7
7.8
7.8
LpA
3
(dBA)
59
61
62
62
Footnotes:
Idle means the state in which the product is doing nothing but running OS, and values for Operating are the maximum of acoustical output for
active HDDs or active processors.
LwA-UL is the upper limit sound power levels (LwA) calculated per section 4.4.1 of ISO 9296 (1988) with data collected in accordance with
ISO 7779 (2010) from a single sample with a total 0.3 bel production deviation applied.
LpA is the A-weighted sound pressure level at the bystander position per section 4.3 of ISO 9296 (1988) and measured in accordance to ISO
7779 (2010). The system is placed in a 24U rack enclosure, 25cm above a reflective floor.
Prominent tone: Criteria of D.6 and D.11 of ECMA-74 12th ed. (2012) are followed to determine if discrete tones are prominent. The system
is placed in center of ISO 7779 table and the acoustic transducers are at front & rear bystander positions.