Reference Guide
704 | Simple Network Management Protocol
www.dell.com | support.dell.com
Table 37-1 lists the traps the RFC-defined SNMP traps and the command used to enable each. Note that the
coldStart and warmStart traps are enabled using a single command.
Enable a subset of Dell Networking enterpriseSpecific SNMP traps using one of the listed command
options Table 37-2 with the command
snmp-server enable traps. Note that the envmon option enables all
environment traps including those that are enabled with the
envmon supply, envmon temperature, and
envmon fan options.
2
Specify which traps the Dell Networking system
sends to the trap receiver.
• Enable all Dell Networking enterpriseSpecific
and RFC-defined traps using the command
snmp-server enable traps from
CONFIGURATION mode.
• Enable all of the RFC-defined traps using the
command
snmp-server enable traps snmp
from CONFIGURATION mode.
snmp-server enable traps
CONFIGURATION
3
Specify the interfaces out of which FTOS sends
SNMP traps.
snmp-server trap-source
CONFIGURATION
Table 37-1. RFC 1157 Defined SNMP Traps on FTOS
Command Option Trap
snmp authentication
SNMP_AUTH_FAIL:SNMP Authentication failed.Request with invalid community string.
snmp coldstart
SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
SNMP_WARM_START: Agent Initialized - SNMP WARM_START.
snmp linkdown
PORT_LINKDN:changed interface state to down:%d
snmp linkup
PORT_LINKUP:changed interface state to up:%d
Step Task Command Command Mode