Reference Guide

iSCSI Optimization | 387
The following message is displayed the first time a Dell EqualLogic array is detected and describes the
configuration changes that are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree port
fast to be enabled on the port of detection.
The following syslog message is generated the first time an EqualLogic array is detected:
%STKUNIT0-M:CP %LLDP-5-LLDP_EQL_DETECTED: EqualLogic Storage Array detected on interface Te 1/
43
At the first detection of an EqualLogic array, an MTU of 12000 for the S4810 and 9252 for S60 is
enabled on all ports and port-channels (if it is has not already been enabled).
Spanning-tree portfast is enabled on the interface identified by LLDP.
Unicast storm control is disabled on the interface identified by LLDP.
Detection and Port Configuration for Dell Compellent Arrays
This feature is available on platforms
Switches support the
iscsi profile-compellent command to configure a port connected to a Dell Compellent
storage array. The command configures a port for the best iSCSI traffic conditions and must be entered in
INTERFACE Configuration mode.
The following message is displayed the first time you use the
iscsi profile-compellent command to
configure a port connected to a Dell Compellent storage array and describes the configuration changes that
are automatically performed:
%STKUNIT0-M:CP %IFMGR-5-IFM_ISCSI_AUTO_CONFIG: This switch is being configured for optimal
conditions to support iSCSI traffic which will cause some automatic configuration to occur
including jumbo frames and flow-control on all ports; no storm control and spanning-tree port
fast to be enabled on the port of detection.
After you execute the iscsi profile-compellent command, the following actions occur:
Jumbo frame size is set to 12000 for the S4810 and 9252 for S55 and S60 on all ports and
port-channels, if it is not already enabled.
Spanning-tree portfast is enabled on the interface.
Unicast storm control is disabled on the interface.
You must enter the
iscsi profile-compellent command in INTERFACE configuration mode. For example:
FTOS(conf-if-te-o/50# iscsi profile-compellent)