Command Line Reference Guide

998 | S-Series Stacking Commands
www.dell.com | support.dell.com
Defaults
None
Command Modes
EXEC Privilege
Command
History
Usage
Information
This command applies to the S60 only.
redundancy disable-auto-reboot
s
Prevent the S-Series stack management unit and standby unit from rebooting if they fails.
Syntax
redundancy disable-auto-reboot [stack-unit | all]
To return to the default, enter no redundancy disable-auto-reboot stack-unit.
Parameters
Defaults
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command
History
Usage
Information
Enabling this command keeps the failed switch in the failed state. It will not reboot until it is manually
rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the
running-config.
Related
Commands
redundancy force-failover stack-unit
s
Force the backup unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults
Not enabled
Command Modes
EXEC Privilege
Version 8.3.3.4 Introduced on S60
stack-unit
Enter the stack member unit identifier of the stack member to reset.
S60 range: 0 - 11
all other S-Series range: 0-7
Version 8.3.3.4 Introduced on S60
Version 8.3.1.0
Added the
all option
Version 7.7.1.0 Introduced on S-Series
show redundancy Display the current redundancy status.