Reference Guide

File Management | 55
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
E-Series Example
Command output example (Partial) on E-Series: show sfm
number
Enter a number to view information on that SFM.
Range: 0 to 8.
all (OPTIONAL) Enter the keyword all to view a table with information on all present SFMs.
brief (OPTIONAL) Enter the keyword brief to view a list with SFM status.
Note: The brief option is not available on C-Series.
Version 8.3.5.3 Updated to support PPID on the S55
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
FTOS#show sfm
Switch Fabric State: up
Switch Mode: SFM3
-- SFM card 0 --
Status : active (Older version of SFM for Exascale)
Card Type : SFM3 - Switch Fabric Module
Up Time : 18 hr, 40 min
Last Restart : remote-off
Temperature : 42C
Power Status : AC
Serial Number : VC074300030
Part Number : 7520020001 Rev 03
Vendor Id : 04
Date Code : 01402006
Country Code : 01
Piece Part ID : CN-0RVY43-75412-123-0030
PPID Revision : 003
Service Tag : SVCTG00
Expr Svc Code : 628 458 860 16
FPGA : 0x0.0.3
Booting from : EEPROM0
-- SFM card 1 --
Status : active (Older version of SFM for Exascale)
Card Type : SFM3 - Switch Fabric Module
Up Time : 18 hr, 40 min
Last Restart : remote-off
Temperature : 42C
Power Status : AC
Serial Number : VC074300032
Part Number : 7520020001 Rev 03
Vendor Id : 04
Date Code : 01402006
Country Code : 01
Piece Part ID : CN-0RVY43-75412-82B-0456
PPID Revision : 1B2
Service Tag : SVCTG01
Expr Svc Code : 628 458 860 17
FPGA : 0x0.0.3
Booting from : EEPROM0
!-------- output truncated -------------!