Command Line Reference Guide

84 | Control and Monitoring
www.dell.com | support.dell.com
Figure 4-6. Command Example: show linecard on Empty C300 Slot
Related
Commands
module power-off
c e
Turn off power to a line card at next reboot.
Syntax
module power-off linecard number
To remove the command from the running configuration, use the no module power-off linecard
number command.
Parameters
Defaults
Not configured.
Command Modes
CONFIGURATION
Command
History
Note: It is advisable to shut down interfaces on a line card that you are hot-swapping.
Force10#show linecard 3
-- Line card 11 --
Status : not present
Force10#linecard 3 ?
E46TB 36-port GE 10/100/1000Base-T with RJ45 - 8-port FE/GE with SFP - 2-port 10GE
with SFP+
E46VB 36-port GE 10/100/1000Base-T with RJ45 and PoE - 8-port FE/GE with SFP -
2-port 10GE with SFP+
E48PB 48-port FE/GE line card with SFP optics (CB)
E48TB 48-port GE 10/100/1000Base-T line card with RJ45 interfaces (CB)
E48VB 48-port GE 10/100/1000Base-T line card with RJ45 interfaces and PoE (CB)
EX4PB 4-port 10GE LAN PHY line card with XFP optics (CB)
EX8PB 8-port 10GE LAN PHY line card with XFP optics (CB)
Force10#linecard 3 EX4PB
Force10#show linecard 3
-- Line card 11 --
Status : not present
Required Type : EX4PB - 4-port 10GE LAN PHY line card with XFP optics (CB)
Force10#
show linecard Display the line card(s) status.
linecard number Enter the keyword line card followed by the line card slot number
C-Series Range: 0-7
E-Series Range: 0 to 13 on a E1200/1200i, 0 to 6 on a E600/E600i, and 0 to 5 on a
E300.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
Version 7.5.1.0 Introduced on C-Series
E-Series original Command