Command Line Reference Guide
604 | iSCSI Optimization
www.dell.com | support.dell.com
show iscsi session detailed
Display detailed information on active iSCSI sessions on the switch.
Syntax
show iscsi session detailed [session isid]
Parameters
Command Mode
EXEC
EXEC Privilege
Command
History
Example
FTOS# show isci session detailed
Session 0 :
-----------------------------------------------------------------------------
Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1
Initiator:iqn.2010-11.com.ixia.ixload:initiator-iscsi-2c
Up Time:00:00:01:28(DD:HH:MM:SS)
Time for aging out:00:00:09:34(DD:HH:MM:SS)
ISID:806978696102
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCPPort ID
10.10.0.44 33345 10.10.0.101 3260 0
Session 1 :
-----------------------------------------------------------------------------
Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1
Initiator:iqn.2010-11.com.ixia.ixload:initiator-iscsi-35
Up Time:00:00:01:22(DD:HH:MM:SS)
Time for aging out:00:00:09:31(DD:HH:MM:SS)
ISID:806978696102
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCPPort ID
10.10.0.53 33432 10.10.0.101 3260 0
Related
Commands
show run iscsi
Display all globally-configured non-default iSCSI settings in the current FTOS session.
Syntax
show run iscsi
Command Mode
EXEC Privilege
Command
History
isid
Enter the session’s iSCSi ID to display detailed information on specified iSCSi session.
Version 8.3.12.0 Introduced on the S4810.
Version 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module
show iscsi Display the currently configured iSCSI settings.
show iscsi session Display information on active iSCSI sessions on the switch.
show run iscsi show run iscsi .
.
Version 8.3.3.8 Introduced on the S60.