Command Line Reference Guide
574 | IPv6 Access Control Lists (IPv6 ACLs)
www.dell.com | support.dell.com
Defaults
Not configured.
Command Modes
ACCESS-LIST
Command
History
Usage
Information
The S-Series supports Ingress IPv6 ACLs.
The S55 supports both Ingress and Egress IPv6 ACLs.
The C-Series cannot count both packets and bytes, so when you enter the count byte options, only
bytes are incremented.
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (gt,
lt
, range) may require more than one entry. The range of ports is configured in the CAM based on
bitmask boundaries; the space required depends on exactly what ports are included in the range.
bit
Enter a flag or combination of bits:
ack: acknowledgement field
fin: finish (no more data from the user)
psh: push function
rst: reset the connection
syn: synchronize sequence numbers
urg: urgent field
count (OPTIONAL) Enter the keyword count to count packets processed by the
filter.
byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter.
log (OPTIONAL) Enter the keyword log to enter ACL matches in the log.
monitor (OPTIONAL) Enter the keyword monitor to monitor traffic on the
monitoring interface specified in the flow-based monitoring session along with
the filter operation.
Version 8.2.1.0 Introduced support on the E-Series ExaScale
Version 7.8.1.0 Introduced support on the C-Series
Version 7.4.1.0 Introduced support on the E-Series
Added
monitor option