link debounce-timer
e
Assign the debounce time for link change notification on this interface.
Syntax
link debounce [milliseconds]
Parameters
Command Modes
INTERFACE
Command
History
Usage
Information
Changes do not affect any ongoing debounces. The timer changes take affect from the next debounce
onward.
monitor
c e s
Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every 5
seconds and the CLI prompt disappears.
Syntax
monitor interface [interface]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
milliseconds
Enter the time to delay link status change notification on this interface.
Range: 100-5000 ms
• Default for copper is 3100 ms
• Default for fiber is 100 ms
Version 8.2.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on E-Series
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
• For an 100/1000 Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
• For the management port, enter the keyword
managementethernet followed
by the slot (0-1) and the port (0).
• For SONET interface types, enter the keyword
sonet followed by the slot/port
information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
Version 8.3.5.0 Introduced on the S55.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.2.1.0 Introduced for E-Series