Command Line Reference Guide
Control and Monitoring | 135
Example
Figure 4-56. Command Example: show system stack-unit
FTOS#show system stack-unit 0
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4810 - 52-port GE/TE/FG (SE)
Current Type : S4810 - 52-port GE/TE/FG (SE)
Master priority : 0
Hardware Rev : 3.0
Num Ports : 64
Up Time : 3 day, 21 hr, 37 min
FTOS Version : 8.3.12.0
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 1.2.0.0
Memory Size : 2147483648 bytes
Temperature : 55C
Voltage : ok
Serial Number : HADL111220134
Part Number : 7590009601 Rev A
Vendor Id : 07
Date Code : 01122011
Country Code : 02
Piece Part ID : N/A
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : N/A
Auto Reboot : disabled
Burned In MAC : 00:01:e8:8a:e1:ab
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus
----------------------------------------------------------------------------
0 0 up AC up
0 1 absent absent
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------------------------------
0 0 up up 11280 up 11520
0 1 up up 11520 up 11280
FTOS#