Command Line Reference Guide

S-Series Debugging and Diagnostics | 1079
Command Modes
EXEC Privilege
Command
History
offline stack-unit
s
Place a stack unit in the offline state.
Syntax
offline stack-unit number
Parameters
Defaults
None
Command Mode
EXEC Privilege
Command
History
H
Related
Commands
H
Usage
Information
You cannot enter this command on a Master or Standby unit.
The system reboots when the off-line diagnostics complete. This is an automatic process. A warning
message appears when the offline stack-unit command is implemented.
Warning - Diagnostic execution will cause stack-unit to reboot after
completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
online stack-unit
s
Place a stack unit in the online state.
Syntax
online stack-unit number
Parameters
Defaults
None
Version 8.3.5.0 Introduced on the S55.
Version 7.7.1.0 Introduced on S-Series
number
Enter the stack unit number.
Unit ID range:
S55: 0-11
all other S-Series: 0-7
Version 8.3.5.0 Introduced on the S55.
Version 8.2.1.0 Added warning message to off-line diagnostic
Version 7.7.1.0 Introduced on S-Series
show environment (S-Series) View S-Series system component status (for example, temperature, voltage).
number
Enter the stack unit number.
Unit ID range:
S55: 0-11
all other S-Series: 0-7