Command Line Reference Guide

Control and Monitoring | 107
E-Series Example
Figure 4-27. Command Example: show linecard on E-Series
C-Series
Example
Figure 4-28. Command Example: show linecard on C-Series
-- Line card 1 --
Status : online
Next Boot : online
Required Type : EXW10SH - 10-port 10GE LAN/WAN PHY line card with
SFP+ options 10M CAM (EH)
Current Type : EXW10SH - 10-port 10GE LAN/WAN PHY line card with
SFP+ options 10M CAM (EH)
Hardware Rev : Base - 1.4 PP0 - 02 PP1 - 02
Num Ports : 10
Up Time : 18 hr, 42 min
FTOS Version : 8-4-1-317
Jumbo Capable : yes
Boot Flash : A: 2.9.1.1c B: 2.9.2.0E0 [booted]
Memory Size : 1073741824 bytes
Temperature : 65C
Power Status : AC
Voltage : ok
Serial Number : FX000049121
Part Number : 7520042807 Rev 03
Vendor Id : 04
Date Code : 01212010
Country Code : 01
Piece Part ID : N/A
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : N/A
Last Restart : soft reset
Auto Reboot : enabled
FTOS#show linecard 11
-- Line card 11 --
Status : online
Next Boot : online
Required Type : E48PF - 48-port GE line card with SFP optics (EF)
Current Type : E48PF - 48-port GE line card with SFP optics (EF)
Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a
Num Ports : 48
Up Time : 12 hr, 37 min
FTOS Version : 6.2.1.x
Jumbo Capable : yes
Boot Flash : A: 2.0.3.4 B: 2.0.3.4 [booted]
Memory Size : 268435456 bytes
Temperature : 49C
Power Status : PEM0: absent or down PEM1: up
Voltage : ok
Serial Number :
Part Number : Rev
Vendor Id :
Date Code :
Country Code :
FTOS#