Command Line Reference Guide
1016 | S-Series Stacking Commands
www.dell.com | support.dell.com
Parameters
Defaults
None
Command Modes
EXEC Privilege
Command
History
Usage
Information
This command applies to the S55 only.
redundancy disable-auto-reboot
s
Prevent a stacked unit from rebooting if it fails.
Syntax
redundancy disable-auto-reboot stack-unit [stack-unit | members]
To return to the default, enter no redundancy disable-auto-reboot stack-unit.
Parameters
Defaults
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command
History
Usage
Information
Enabling this command keeps the failed switch in the failed state. It will not reboot until it is manually
rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the
running-config.
• Disable reboot on the Master unit: redundancy disable-auto-reboot stack-unit
• Disable reboot on a specific unit: redundancy disable-auto-reboot stack-unit 1
• Disable reboot on all stacked units: redundancy disable-auto-reboot stack-unit members
Related
Commands
redundancy force-failover stack-unit
s
Force the backup unit in the stack to become the management unit.
Syntax
redundancy force-failover stack-unit
Defaults
Not enabled
stack-unit
Enter the stack member unit identifier of the stack member to reset.
S55 range: 0 - 11
Version 8.3.5.1 Introduced on S55
stack-unit
(Optional) Enter the stack member unit identifier of the stack member to reset.
S55 range: 0 - 11
members
(Optional) Prevent the reboot for all stack members.
Version 8.3.5.1 Introduced on S55
Version 8.3.1.0
Added the
all option
Version 7.7.1.0 Introduced on S-Series
show redundancy Display the current redundancy status.