Reference Guide

Simple Network Management Protocol | 663
To configure the system from the manumitting station using SNMP:
Subscribe to Managed Object Value Updates using SNMP
By default, the Dell Networking system displays some unsolicited SNMP messages (traps) upon certain
events and conditions. You can also configure the system to send the traps to a management station. Traps
cannot be saved on the system.
FTOS supports the following three sets of traps:
RFC 1157-defined traps: coldStart, warmStart, linkDown, linkUp, authenticationFailure,
egpNeighbborLoss
Dell Force10 enterpriseSpecific environment traps: fan, supply, temperature
Dell Force10 enterpriseSpecific protocol traps: bgp, ecfm, stp, xstp,
To configure the system to send SNMP notifications:
Identify the physical location of the system. For example, San
Jose, 350 Holger Way, 1st floor lab, rack A1-1. You may use up
to 55 characters.
Default: None
snmp-server location text CONFIGURATION
Task Command Command Mode
Identify the system manager along with this person’s
contact information (e.g E-mail address or phone
number). You may use up to 55 characters.
Default: None
snmpset -v version -c community
agent-ip sysContact.0 s “contact-info
CONFIGURATION
Identify the physical location of the system. For
example, San Jose, 350 Holger Way, 1st floor lab,
rack A1-1. You may use up to 55 characters.
Default: None
snmpset -v version -c community
agent-ip sysLocation.0 s “location-info
CONFIGURATION
Step Task Command Command Mode
1 Configure the Dell Networking system send
notifications to an SNMP server.
snmp-server host ip-address
CONFIGURATION
Task Command Command Mode