Reference Guide
iSCSI Optimization | 363
iSCSI Optimization Prerequisites
• iSCSI optimization requires LLDP on the switch. LLDP is enabled by default (refer to Chapter 21,
Link Layer Discovery Protocol).
Configuring iSCSI Optimization
To configure iSCSI optimization on a switch, follow these steps:
Displaying iSCSI Optimization Information
Use the show commands in Table 18-1 to display information on iSCSI optimization
Step Task Command Command Mode
1 (Optional) Enter interface configuration mode to
configure the auto-detection of Compellent disk
arrays.
interface port-type slot/port CONFIGURATION
2 (Optional) Configures the auto-detection of
Compellent arrays on a port.
Default: Compellent disk arrays are not detected.
[no] iscsi profile-compellent
INTERFACE
Table 18-1. Displaying iSCSI Optimization Information
Command Output
show run iscsi Displays all globally-configured non-default iSCSI settings in the current
FTOS session.