Command Reference Guide

Control and Monitoring | 97
Command
History
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service
timestamps debug uptime
in the running-configuration.
Use the show running-config command to view the current options set for the service
timestamps command.
show alarms
c e s
View alarms for the RPM, SFMs, line cards and fan trays.
Syntax
show alarms [threshold]
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Example
(E-Series)
FTOS# show alarms
-- Minor Alarms --
Alarm Type Duration
----------------------------------------------------
RPM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 0 PEM A failed or rmvd 7 hr, 37 min
SFM 1 PEM A failed or rmvd 7 hr, 37 min
SFM 2 PEM A failed or rmvd 7 hr, 37 min
SFM 3 PEM A failed or rmvd 7 hr, 37 min
SFM 4 PEM A failed or rmvd 7 hr, 37 min
SFM 5 PEM A failed or rmvd 7 hr, 37 min
SFM 6 PEM A failed or rmvd 7 hr, 37 min
SFM 7 PEM A failed or rmvd 7 hr, 36 min
line card 1 PEM A failed or rmvd 7 hr, 36 min
line card 4 PEM A failed or rmvd 7 hr, 36 min
only 8 SFMs in chassis 7 hr, 35 min
-- Major Alarms --
Alarm Type Duration
----------------------------------------------------
No major alarms
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
threshold
(OPTIONAL) Enter the keyword threshold to display the temperature thresholds
set for the line cards, RPM, and SFMs.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command