Command Reference Guide
94 | Control and Monitoring
www.dell.com | support.dell.com
Related
Commands
reload
c e s
Reboot FTOS.
Syntax
reload
Command Modes
EXEC Privilege
Command
History
Usage
Information
If there is a change in the configuration, FTOS will prompt you to save the new configuration.
Or you can save your running configuration with the
copy running-config command.
Related
Commands
reset
c e
Reset a line card, RPM, or a failed SFM (TeraScale only).
Syntax
reset {linecard number [hard | power-cycle] | rpm number [hard | power-cycle] | standby}
Parameters
Defaults
Disabled.
power-off Power off a line card or standby SFM.
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
reset Reset a line card, RPM, or a failed SFM (TeraScale and ExaScale).
reset stack-unit Reset any designated stack member except the management unit
linecard number Enter the keyword linecard and a number for the line card slot number.
(Optional) Add the keyword hard or power-cycle (power-cycle is C-Series
only) to power cycle the line card.
C-Series Range: 0-7
E-Series Range: 0 to 13 on E1200/E1200i, 0 to 6 on E600/E600i, and 0 to 5
on E300
hard
Enter the keyword hard to power cycle the line card.
power-cycle
Enter the keyword power-cycle after upgrading a C-Series FPGA to cause
the FPGA to be reprogrammed based on the contents of the FPGA PROM.
Note: This option is supported on C-Series only.
rpm number Enter the keyword rpm followed by a number for the RPM slot number.
(Optional) Add the keyword hard or power-cycle (C-Series only) to power
cycle the RPM.
Range: 0 to 1
sfm slot number Enter the keyword sfm followed by the failed or powered-off SFM slot
number.
Note: Supported on E-Series only