Command Reference Guide
Control and Monitoring | 75
enable
c e s
Enter the EXEC Privilege mode or any other privilege level configured. After entering this
command, you may need to enter a password.
Syntax
enable [level]
Parameters
Defaults
15
Command Modes
EXEC
Command
History
Usage
Information
Users entering the EXEC Privilege mode or any other configured privilege level can access
configuration commands. To protect against unauthorized access, use the
enable password
command to configure a password for the
enable command at a specific privilege level. If no
privilege level is specified, the default is privilege level 15.
Related
Commands
enable optic-info-update interval
Enable polling intervals of optical information updates for SNMP.
Syntax
enable optical-info-update interval seconds
To disable optical power information updates, use the no enable optical-info-update interval
command.
Parameters
Defaults
Disabled
Command Modes
CONFIGURATION
Command
History
level (OPTIONAL) Enter a number for a privilege level of FTOS.
Range: 0 to 15.
Default: 15
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
enable password Configure a password for the enable command and to access a privilege level.
interval seconds
Enter the keyword interval followed by the polling interval in seconds.
Range: 120 to 6000 seconds
Default: 300 seconds (5 minutes)
Version 8.3.10.0 Replacement command for S4810 only. Replaces the enable
xfp-power-updates command.