Command Reference Guide

Control and Monitoring | 67
Command Modes
CONFIGURATION
Command
History
Usage
Information
You must save the configuration and reload the system to implement ASF. When you enter the
command, the system sends a message stating that the new mode is enabled when the system
reloads.
audible cut-off
e
Turn off an audible alarm.
Syntax
audible cut-off
Defaults
Not configured.
Command Modes
EXEC Privilege
banner exec
c e s
Configure a message that is displayed when a user enters the EXEC mode.
Syntax
banner exec c line c
Parameters
Defaults
No banner is displayed.
Command Modes
CONFIGURATION
Command
History
Usage
Information
Optionally, use the banner exec command to create a text string that is displayed when the
user accesses the EXEC mode. The
exec-banner command toggles that display.
Example
FTOS(conf)#banner exec ?
LINE c banner-text c, where 'c' is a delimiting character
FTOS(conf)#banner exec %
Version 8.3.11.0 Introduced on the Z9000
Version 8.3.7.0 Introduced on the S4810.
c Enter the keywords banner exec, and then enter a character delineator,
represented here by the letter c, and press ENTER.
line Enter a text string for your banner message ending the message with your
delineator.
In the example below, the delineator is a percent character (%); the banner
message is “testing, testing”.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command