Command Reference Guide
High Availability (HA) | 541
Syntax
redundancy sfm standby
Place the SFM in an online state using the command no redundancy sfm standby command.
Defaults
The SFM is online by default.
Command Modes
CONFIGURATION
Command
History
Command
History
Usage
Information
When a secondary RPM with logical SFM is inserted or removed, the system must add or
remove the backplane links to the switch fabric trunk. To avoid traffic disruption, use this
command when the secondary RPM is inserted. When this command is executed, the logical
SFM on the standby RPM is immediately taken offline and the SFM state is set as “standby”.
Example
FTOS#show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 active
FTOS#configure
FTOS(conf)#redundancy sfm standby
Taking secondary SFM offline...
!
FTOS(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 standby
FTOS(conf)#no redundancy sfm
Taking secondary SFM online...
!
FTOS(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 active
Version 7.5.1.0 Introduced on C-Series
Version 8.3.12.0 Introduced on the S4810.
Version 7.5.1.0 Introduced on C-Series Only
Note: This command could affect traffic when taking the secondary SFM offline.