Command Reference Guide
802.1ag | 155
database hold-time
s
Set the amount of time that data from a missing MEP is kept in the Continuity Check
Database.
Syntax
database hold-time minutes
Parameters
Defaults
100 minutes
Command Modes
ECFM DOMAIN
Command
History
disable
s
Disable Ethernet CFM without stopping the CFM process.
Syntax
disable
Defaults
Disabled
Command Modes
ETHERNET CFM
Command
History
domain
s
Create a maintenance domain.
Syntax
domain
name md-level number
Parameters
Defaults
None
Command Modes
ETHERNET CFM
minutes
Enter a hold-time.
Range: 100-65535 minutes
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on S-Series
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on S-Series
name
Name the maintenance domain.
md-level number Enter a maintenance domain level.
Range: 0-7