Command Reference Guide
138 | Control and Monitoring
www.dell.com | support.dell.com
Example
(show system
brief)
FTOS#show system brief
Stack MAC : 0:1:e8:d6:4:70
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Member not present
1 Standby online S50V S50V 7.7.1.0 52
2 Mgmt online S50V S50V 7.7.1.0 52
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Module Info --
Unit Module No Status Module Type Ports
---------------------------------------------------------------------------
1 0 online S50-01-10GE-2P 2
1 1 online S50-01-24G-2S 1
2 0 online S50-01-10GE-2P 2
2 1 online S50-01-24G-2S 1
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
1 0 up AC
1 1 absent
2 0 up AC
2 1 absent
-- Fan Status --
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
------------------------------------------------------------------------------
1 up up up up up up up
2 up up up up up up up
FTOS#
Example
(show system
stack-unit)
FTOS#show system stack-unit 0
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S50V - 48-port E/FE/GE with POE (SB)
Current Type : S50V - 48-port E/FE/GE with POE (SB)
Master Priority : 4
Hardware Rev : 2.0
Num Ports : 52
Up Time : 3 hr, 17 min
FTOS Version : 7.6.1.0a
Jumbo Capable : yes
POE Capable : no
Boot Flash : Present
Memory Size : 254701568 bytes
Temperature : 43C
Voltage : ok
Serial Number : DZ267160000
Part Number : 7590003600 Rev B
Vendor Id : 07
Date Code : 12172007
Country Code : 01