Command Reference Guide

1374 | Simple Network Management Protocol and Syslog
www.dell.com | support.dell.com
Syntax
snmp-server enable traps [notification-type] [notification-option]
To disable traps, use the
no snmp-server enable traps [notification-type] [notification-option]
command.
Parameters
Defaults
Not enabled.
Command Modes
CONFIGURATION
Command
History
Usage
Information
FTOS supports up to 16 SNMP trap receivers.
For the
cam-utilization notification option, the system will generate syslogs and SNMP traps
when the L3 host table or route table utilization goes above the threshold. This applies to the
S4810 only.
notification-type
Enter the type of notification from the list below:
bgp—Notification of changes in BGP process
ecfm Notification of changes to ECFM
envmon—For Dell Force10, device notifications when an
environmental threshold is exceeded
isis — Notification of intermediate service traps.
lacp Notification of changes to
snmp—Notification of RFC 1157 traps.
stp —Notification of state change in Spanning Tree protocol (RFC
1493)
vlt—Notification of virtual link trunking
vrrp—Notification of state change in a VRRP group
xstp—Notification of state change in MSTP (802.1s), RSTP
(802.1w), and PVST+
notification-option
For the envmon notification-type, enter one of the following optional
parameters:
cam-utilization
fan
supply
temperature
For the snmp notification-type, enter one of the following optional
parameters:
authentication
coldstart
linkdown
linkup
Version 8.3.11.1 Introduced on Z9000
Version 8.3.7.0 Introduced on S4810
Version 8.4.1.0 Support was added for VRRP traps.
Version 7.6.1.0 Support added for S-Series; Added support for STP and xSTP traps.
Version 7.5.1.0 Support added for C-Series
E-Series legacy command