Switch fabric backplane link status:
SFM0 Links Status SFM1 Links Status
LC SlotID Port0 | Port1 | Port2 | Port3 | Port4 | Port5 | Port6 | Port7
0 up up up up down down down down
1 not present
2 not present
3 not present
4 not present
5 not present
6 up up up up down down down down
7 not present
up - Both ends of the link are up
down - Both ends of the link are down
up / down - SFM side up and LC side down
down / up - SFM side down and LC side up
FTOS#
show system (S-Series and S4810)
s
Display the current status of all units in the system.
Syntax
show system [brief | stack-unit unit-id]
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
The second example shows the output from the show system brief command.
The last example shows the output from the
show system stack-unit command.
Example
(show system)
FTOS#show system
Stack MAC : 00:01:e8:8b:3e:42
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4810 - 52-port GE/TE/FG (SE)
brief
(OPTIONAL) Enter the keyword brief to view an abbreviated list of
system information.
stack-unit unit-id (OPTIONAL) Enter the keyword stack-unit followed by the stack
member ID for information on that stack member.
Range: 0 to 7.
Version 7.8.1.0 Modified output: Boot Flash field will display code level for boot code 2.8.1.1
and newer, while older boot codes are displayed as “Present”
Version 7.7.1.0 Modified output: Added Master Priority field.
Version 7.6.1.0 Introduced for S-Series switches