Command Reference Guide

Remote Monitoring (RMON) | 1257
Parameters
Defaults
as described above
Command Modes
CONFIGURATION
Command
History
rmon hc-alarm
c e s z
Set an alarm on any MIB object.
Syntax
rmon hc-alarm number variable interval {delta | absolute} rising-threshold value event-number
falling-threshold value event-number [owner string]
To disable the alarm, use the
no rmon hc-alarm number command.
Parameters
number
Assign an event number in integer format from 1 to 65535. The
number value must be unique in the RMON Event Table.
log
(OPTIONAL) Enter the keyword log to generate an RMON log
entry. The log entry is triggered and sets the eventType in the RMON
MIB to log or log-and-trap.
Default: No log
trap community
(OPTIONAL) Enter the keyword trap followed by an SNMP
community string to configure the eventType setting in the RMON
MIB. This sets either snmp-trap or log-and-trap.
Default: public
description string
(OPTIONAL) Enter the keyword description followed by a string
describing the event.
owner name
(OPTIONAL) Enter the keyword owner followed by the name of the
owner of this event.
Version 8.3.11.1 Introduced on Z9000
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Support added for S-Series
Version 7.5.1.0 Support added for C-Series
Version 6.1.1.0 Introduced for E-Series
number
Enter the alarm integer number from 1 to 65535. The value must be
unique in the RMON Alarm Table.
variable
The MIB object to monitor. The variable must be in the SNMP OID
format, for example, 1.3.6.1.2.1.1.3 The object type must be a 64 bit
integer.
interval
Time, in seconds, the alarm monitors the MIB variables; this is the
alarmSampleType in the RMON Alarm table.
Range: 5 to 3600 seconds
delta Enter the keyword delta to test the change between MIB variables.
This is the alarmSampleType in the RMON Alarm table.