Command Reference Guide
Remote Monitoring (RMON) | 1255
Default
owner
Command Modes
CONFIGURATION
Command
History
rmon collection history
c e s z
Enable the RMON MIB history group of statistics collection on an interface.
Syntax
rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds]
To remove a specified RMON history group of statistics collection, use the
no rmon collection
history
{controlEntry integer} command.
Parameters
Defaults
No default behavior
falling-threshold value
event-number
Enter the keyword falling-threshold followed by the value (32bit)
the falling-threshold alarm is either triggered or reset. Then
enter the event-number to trigger when the falling threshold
exceeds its limit.
This value is the same as the alarmFallingEventIndex or the
alarmTable of the RMON MIB. If there is no corresponding
falling-threshold event, the value is zero.
owner string
(OPTIONAL) Enter the keyword owner followed by the owner
name to specify an owner for the alarm. This is the alarmOwner
object in the alarmTable of the RMON MIB.
Version 8.3.11.1 Introduced on Z9000
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Support added for S-Series
Version 7.5.1.0 Support added for C-Series
Version 6.1.1.0 Introduced for E-Series
controlEntry integer
Enter the keyword controlEntry to specify the RMON group of
statistics using a value. Then enter an integer value from 1 to 65535
that identifies the RMON group of statistics. The integer value must
be a unique index in the RMON History Table.
owner name
(OPTIONAL) Enter the keyword owner followed by the owner
name to record the owner of the RMON group of statistics.
buckets number
(OPTIONAL) Enter the keyword buckets followed the number of
buckets for the RMON collection history group of statistics.
Bucket Range: 1 to 1000
Default: 50
interval seconds
(OPTIONAL) Enter the keyword interval followed the number of
seconds in each polling cycle.
Range: 5 to 3600 seconds
Default: 1800 seconds