Command Reference Guide
112 | Control and Monitoring
www.dell.com | support.dell.com
Required Type : E48PF - 48-port GE line card with SFP optics (EF)
Current Type : E48PF - 48-port GE line card with SFP optics (EF)
Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a
Num Ports : 48
Up Time : 11 hr, 24 min
FTOS Version : 6.1.1.0
Jumbo Capable : yes
FTOS#
Table 4-1 list the definitions of the fields shown in the examples.
Table 4-1. Descriptions for show linecard output
Field Description
Line card Displays the line card slot number (only listed in show linecard all
command output).
Status Displays the line card’s status.
Next Boot Displays whether the line card is to be brought online at the next
system reload.
Required Type Displays the line card type configured for the slot.
The Required Type and Current Type must match. Use the
linecard command to reconfigure the line card type if they do not
match.
Current Type Displays the line card type installed in the slot.
The Required Type and Current Type must match. Use the
linecard command to reconfigure the line card type if they do not
match.
Hardware Rev Displays the chip set revision.
Num Ports Displays the number of ports in the line card.
Up Time Displays the number of hours and minutes the card is online.
FTOS Version Displays the operating software version.
Jumbo Capable Displays Yes or No indicating if the line card can support Jumbo
frames.
Boot Flash Ver Displays the two possible Bootflash versions. The [Booted]
keyword next to the version states which version was used at
system boot.
Memory Size List the memory of the line card processor.
Temperature Displays the temperature of the line card.
Minor alarm status if temperature is over 65° C.
Power Status Lists the type of power modules used in the chassis:
• AC = AC power supply
• DC = DC Power Entry Module (PEM)
Voltage Displays OK if the line voltage is within range.
Serial Number Displays the line card serial number.
Part Num Displays the line card part number.