Command Reference Guide

1028 | Object Tracking
www.dell.com | support.dell.com
debug track
c e s
Enables debugging for tracked objects.
Syntax
debug track [all | notifications | object-id]
Parameters
Defaults Enable debugging on the state and notifications of all tracked objects (debug track all).
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS#debug track all
04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface GigabitEthernet 0/2
line-protocol DOWN
04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN
delay
c e s
Configure the time delay used before communicating a change in the status of a tracked object to
clients.
Syntax
delay {[up seconds] [down seconds]}
To return to the default setting, enter no delay.
Parameters
Defaults
0 seconds
Command Modes
OBJECT TRACKING (conf_track_object-id)
Command
History
all
Enables debugging on the state and notifications of all tracked objects.
notifications
Enables debugging on the notifications of all tracked objects.
object-id
Enables debugging on the state and notifications of the specified tracked object. Range:
1 to 65535.
Version 8.3.12.0 Introduced on the S4810.
Version 8.4.1.0 Introduced
seconds
Enter the number of seconds the object tracker waits before sending a notification about
the change in the UP and/or DOWN state of a tracked object to clients.
Range: 0 to 180
Default: 0 seconds.
Version 8.3.12.0 Introduced on the S4810.
Version 8.4.1.0 Introduced