Specifications

Installing the S25P System 29
This chapter contains these major sections:
Accessing the Console Port
Installing Optics on page 30
Installing SFPs on page 31
Installing XFPs on page 32
Accessing the Console Port
To access the console port, use the following procedure.
Chapter 4 Installing Ports
Connect the RJ-45/DB-9
adapter that is shipped with
the S25P system to the
RJ-45 cable.
Console port pinout:
Pin 1 = NC
Pin 2 = NC
Pin 3 = RXD
Pin 4 = GND
Pin 5 = GND
Pin 6 = TXD
Pin 7 = NC
Pin 8 = NC
Figure 18 Console Port of S25P Set your initial console terminal settings
to match the default console settings on
the switch:
9600 baud rate
•No parity
8 data bits
1 stop bit
No flow control (console port
only)
After establishing a connection, you can
modify the settings to match at each end
of the connection.
Step Task
1
Install the RJ-45 copper cable that is shipped with the S25P system into the console port.
Caution:
You must install a straight-through RJ-45 copper cable (a standard Ethernet cable) into the
console port. This is different from many other implementations that require an Ethernet crossover
cable (or rollover cable). If connecting to a terminal server and using a crossover cable, daisychain
another crossover cable to effectively get a straight-through cable connection. Many console terminal
servers use octopus cables that are crossover cables. To accommodate the octopus cable, connect an
additional crossover cable, as above, to effectively install a straight-through cable.
fn00159s25P
P28
27
XFP26
AC1
XFP25
AC2
Alarm
Stack ID