Specifications
Installing the S25P System 29
This chapter contains these major sections:
• Accessing the Console Port
• Installing Optics on page 30
— Installing SFPs on page 31
— Installing XFPs on page 32
Accessing the Console Port
To access the console port, use the following procedure.
Chapter 4 Installing Ports
Connect the RJ-45/DB-9
adapter that is shipped with
the S25P system to the
RJ-45 cable.
Console port pinout:
Pin 1 = NC
Pin 2 = NC
Pin 3 = RXD
Pin 4 = GND
Pin 5 = GND
Pin 6 = TXD
Pin 7 = NC
Pin 8 = NC
Figure 18 Console Port of S25P Set your initial console terminal settings
to match the default console settings on
the switch:
• 9600 baud rate
•No parity
• 8 data bits
• 1 stop bit
• No flow control (console port
only)
After establishing a connection, you can
modify the settings to match at each end
of the connection.
Step Task
1
Install the RJ-45 copper cable that is shipped with the S25P system into the console port.
Caution:
You must install a straight-through RJ-45 copper cable (a standard Ethernet cable) into the
console port. This is different from many other implementations that require an Ethernet crossover
cable (or rollover cable). If connecting to a terminal server and using a crossover cable, daisychain
another crossover cable to effectively get a straight-through cable connection. Many console terminal
servers use octopus cables that are crossover cables. To accommodate the octopus cable, connect an
additional crossover cable, as above, to effectively install a straight-through cable.
fn00159s25P
P28
27
XFP26
AC1
XFP25
AC2
Alarm
Stack ID