Reference Guide

98 | Control and Monitoring
www.dell.com | support.dell.com
Usage
Information
When you enter the ping command without specifying an IP/IPv6 address (Extended Ping), you are
prompted for a target IP/IPv6 address, a repeat count, a datagram size (up to 1500 bytes), a timeout in
seconds, and for Extended Commands. See Appendix , for information on the ICMP message codes
that return from a ping command.
Figure 5-8. Command Example: ping (IPv4)
Figure 5-9. Command Example: ping (IPv6)
power-off
c e
Turn off power to a selected line card or the standby (extra) Switch Fabric Module (SFM).
Syntax
power-off {linecard number | sfm sfm-slot-id}
Parameters
Defaults
Disabled
Command Modes
EXEC Privilege
Command
History
FTOS#ping 172.31.1.255
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds:
Reply to request 1 from 172.31.1.208 0 ms
Reply to request 1 from 172.31.1.216 0 ms
Reply to request 1 from 172.31.1.205 16 ms
:
:
Reply to request 5 from 172.31.1.209 0 ms
Reply to request 5 from 172.31.1.66 0 ms
Reply to request 5 from 172.31.1.87 0 ms
FTOS#
FTOS#ping 100::1
Type Ctrl-C to abort.
Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds:
!!!!!
Success rate is 100.0 percent (5/5), round-trip min/avg/max = 0/0/0 (ms)
FTOS#
linecard number Enter the keyword linecard and a number for the line card slot number.
C-Series Range: 0 to 7
E-Series Range: 0 to 13 on a E1200/E1200i, 0 to 6 on a E600/E600i, and 0 to 5 on a
E300.
sfm sfm-slot-id Enter the keyword sfm by the slot number of the SFM to which you want to turn
off power.
Note: This option is supported on E-Series only.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
Version 7.5.1.0 Introduced on C-Series
E-Series original Command