Reference Guide
698 | IPv6 Access Control Lists (IPv6 ACLs)
www.dell.com | support.dell.com
Parameters
Defaults
Not configured.
Command Modes
ACCESS-LIST
Command
History
Usage
Information
The C-Series cannot count both packets and bytes, so when you enter the count byte options, only
bytes are incremented.
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (gt,
lt, range) may require more than one entry. The range of ports is configured in the CAM based on
bitmask boundaries; the space required depends on exactly what ports are included in the range.
source address
Enter the IPv6 address of the network or host from which the packets were sent
in the
x:x:x:x::x format followed by the prefix length in the /x format.
Range: /0 to /128
The
:: notation specifies successive hexadecimal fields of zero.
mask Enter a network mask in /prefix format (/x).
any Enter the keyword any to specify that all routes are subject to the filter.
host ipv6-address Enter the keyword host followed by the IPv6 address of the host in the
x:x:x:x::x format.
The
:: notation specifies successive hexadecimal fields of zero
operator
(OPTIONAL) Enter one of the following logical operand:
•
eq = equal to
•
neq = not equal to
•
gt = greater than
•
lt = less than
•
range = inclusive range of ports (you must specify two ports for the port
parameter.)
port port
(OPTIONAL) Enter the application layer port number. Enter two port numbers
if using the
range logical operand.
Range: 0 to 65535
destination address
Enter the IPv6 address of the network or host to which the packets are sent in
the
x:x:x:x::x format followed by the prefix length in the /x format.
Range: /0 to /128
The
:: notation specifies successive hexadecimal fields of zero.
count (OPTIONAL) Enter the keyword count to count packets processed by the
filter.
byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter.
log (OPTIONAL) Enter the keyword log to enter ACL matches in the log.
monitor (OPTIONAL) Enter the keyword monitor to monitor traffic on the
monitoring interface specified in the flow-based monitoring session along with
the filter operation.
Version 8.4.2.1 Introduced on the S-Series
Version 8.2.1.0 Introduced support on the E-Series ExaScale
Version 7.8.1.0 Introduced support on the C-Series
Version 7.4.1.0 Introduced support on the E-Series TeraScale
Added
monitor option