Reference Guide
582 | Interfaces
www.dell.com | support.dell.com
link debounce-timer
e
Assign the debounce time for link change notification on this interface.
Syntax
link debounce [milliseconds]
Parameters
Command Modes
INTERFACE
Command
History
Usage
Information
Changes do not affect any ongoing debounces. The timer changes take affect from the next debounce
onward.
monitor
c e s
Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every 5
seconds and the CLI prompt disappears.
Syntax
monitor interface [interface]
To disable monitoring and return to the CLI prompt, press the q key.
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Information
The delta column displays changes since the last screen refresh.
milliseconds
Enter the time to delay link status change notification on this interface.
Range: 100-5000 ms
• Default for copper is 3100 ms
• Default for fiber is 100 ms
Version 8.2.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on E-Series
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
• For an 100/1000 Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
• For the management port, enter the keyword
managementethernet followed by
the slot (0-1) and the port (0).
• For a SONET interface, enter the keyword
sonet followed by the slot/port.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.2.1.0 Introduced for E-Series