Reference Guide

Interfaces | 575
interface range
c e s
This command permits configuration of a range of interfaces to which subsequent commands are
applied (bulk configuration). Using the interface range command, identical commands can be
entered for a range of interface.
Syntax
interface range interface , interface , ...
Parameters
Defaults
This command has no default behavior or values.
Command Modes
CONFIGURATION
Command
History
Usage
Information
When creating an interface range, interfaces appear in the order they are entered; they are not sorted.
The command verifies that interfaces are present (physical) or configured (logical). Important things to
remember:
Bulk configuration is created if at least one interface is valid.
Non-existing interfaces are excluded from the bulk configuration with a warning message.
The interface range prompt includes interface types with slot/port information for valid interfaces.
The prompt allows for a maximum of 32 characters. If the bulk configuration exceeds 32
characters, it is represented by an ellipsis ( ... ).
When the interface range prompt has multiple port ranges, the smaller port range is excluded from
the prompt.
If overlapping port ranges are specified, the port range is extended to the smallest start port and the
biggest end port.
interface ,
interface , ...
Enter the keyword interface range and one of the interfaces — slot/port,
port-channel or VLAN number. Select the range of interfaces for bulk configuration.
You can enter up to six comma separated ranges—spaces are not required between the
commas. Comma-separated ranges can include VLANs, port-channels and physical
interfaces.
Slot/Port information must contain a space before and after the dash. For example,
interface range gigabitethernet 0/1 - 5 is valid; interface range
gigabitethernet 0/1-5 is not valid.
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
For a Port Channel interface, enter the keyword
port-channel followed by a
number:
C-Series and S-Series Range: 1-128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512 for
ExaScale.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
For a VLAN, enter the keyword
vlan followed by a number from 1 to 4094.
Version 8.2.1.0 Support for 4093 VLANs on E-Series ExaScale. Prior releases supported 2094.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.1.1.0 Introduced for E-Series