Reference Guide

High Availability (HA) | 541
Example
Figure 21-3. redundancy sfm standby Command Example
Related
Commands
redundancy synchronize
c e
Manually synchronize data once between the Primary RPM and the Secondary RPM.
Syntax
redundancy synchronize [full | persistent-data | system-data]
Parameters
Defaults
Not configured.
Command Modes
EXEC Privilege
Command
History
FTOS#show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 active
FTOS#configure
FTOS(conf)#redundancy sfm standby
Taking secondary SFM offline...
!
FTOS(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 standby
FTOS(conf)#no redundancy sfm
Taking secondary SFM online...
!
FTOS(conf)#do show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 active
show sfm Display the SFM status
show switch links Display the switch fabric backplane or internal status.
full Enter the keyword full to synchronize all data.
persistent-data Enter the keywords persistent-data to synchronize the startup configuration
between RPMs.
system-data Enter the keywords system-data to synchronize persistent-data and the running
configuration file, event log, SFM and line card states.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.5.1.0 Introduced on C-Series
Version 7.6.1.0 Introduced on E-Series