Reference Guide
482 | Far-End Failure Detection (FEFD)
www.dell.com | support.dell.com
Parameters
Defaults
15 seconds
Command Modes
INTERFACE
fefd-global interval
e
Configure an interval between FEFD control packets.
Syntax
fefd-global interval seconds
To return to the default value, enter no fefd-global interval.
Parameters
Defaults
15 seconds
Command Modes
CONFIGURATION
fefd reset
e
Reset all interfaces or a singe interface that was in “error-disabled” mode.
Syntax
fefd reset [interface]
Parameters
Defaults
Not configured.
Command Modes
EXEC Privilege
show fefd
e
View FEFD status globally or on a specific interface.
Syntax
show fefd [interface]
seconds
Enter a number as the time between FEFD control packets.
Range: 3 to 300 seconds
Default: 15 seconds
seconds
Enter a number as the time between FEFD control packets.
Range: 3 to 300 seconds
Default: 15 seconds
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
• For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.