Reference Guide
312 | Bidirectional Forwarding Detection (BFD)
www.dell.com | support.dell.com
Example
Figure 11-2. show bfd counters Command Example
show bfd neighbors
c e
Display BFD neighbor information on all interfaces or a specified interface.
Syntax
show bfd neighbors interface [detail]
Parameters
Defaults
None
Command Modes
EXEC
EXEC Privilege
Command
History
FTOS#show bfd counters
Interface Tx Rx
GigabitEthernet 1/3 522 625
FTOS#
interface
Enter one of the following keywords and slot/port or number information:
• For a 1-Gigabit Ethernet interface, enter the keyword
gigabitethernet followed by the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet followed by the slot/port information.
• For a SONET interface, enter the keyword
sonet followed by the slot/
port information.
• For a Port Channel interface, enter the keyword
port-channel
followed by a number:
C-Series and S-Series Range: 1-128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale, and 1 to
512 for ExaScale
• For VLAN interfaces, enter the keyword
vlan followed by a number
from 1 to 4094. For ExaScale VLAN interfaces, the range is 1-2730
(VLAN IDs can be 0-4093).
detail (OPTIONAL) Enter the keyword detail to view detailed information about
BFD neighbors.
Version 8.4.2.5 Added support for BFD for BGP on the C-Series and E-Series TeraScale.
Version 8.3.7.0 Added support for BFD for BGP on the S4810.
Version 8.3.8.0 Added support for BFD for BGP on the S4810.
Version 8.4.1.3 Added support for BFD for BGP on the E-Series ExaScale.
Version 8.2.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on C-Series
Version 7.5.1.0 Added BFD on VLAN and port-channel interfaces on E-Series
Version 7.4.1.0 Introduced BFD on physical ports on E-Series