Reference Guide

306 | Bidirectional Forwarding Detection (BFD)
www.dell.com | support.dell.com
clear bfd counters
c e
Clear all BFD counters, or counters for a particular interface.
Syntax
clear bfd counters [interface]
Parameters
Defaults
None
Command Modes
EXEC Privilege
Command
History
Related
Commands
interface
(OPTIONAL) Enter one of the following keywords and slot/port or number
information:
For a 1-Gigabit Ethernet interface, enter the keyword
gigabitethernet
followed by the slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword
tengigabitethernet
followed by the slot/port information.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a port-channel interface, enter the keyword
port-channel followed by a
number:
C-Series and S-Series Range: 1-128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale, and 1 to 512 for
ExaScale
For VLAN interfaces, enter the keyword
vlan followed by a number from 1 to
4094. For ExaScale VLAN interfaces, the range is 1-2730 (VLAN IDs can be
0-4093).
Version 8.2.1.0 Introduced on E-Series ExaScale
Version 7.7.1.0 Introduced on C-Series
Version 7.5.1.0 Added support for VLAN and port-channel interfaces on E-Series
Version 7.4.1.0 Introduced on E-Series
show bfd counters Display BFD counter information.