Reference Guide

168 | 802.1ag
www.dell.com | support.dell.com
Syntax
ethernet cfm
Defaults
Disabled
Command Modes
CONFIGURATION
Command
History
ethernet cfm mep
s
Create an MEP.
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-name name mepid
mep-id
Parameters
Defaults
None
Command Modes
INTERFACE
Command
History
ethernet cfm mip
s
Create an MIP.
Syntax
ethernet cfm mip domain {name | level} ma-name name
Parameters
Defaults
None
Command Modes
INTERFACE
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on S-Series
[up-mep | down-mep]
Specify whether the MEP is up or down facing.
Up-MEP: monitors the forwarding path internal to an bridge on the
customer or provider edge; on Dell Force10 systems the internal forwarding
path is effectively the switch fabric and forwarding engine.
Down-MEP: monitors the forwarding path external another bridge.
domain [name | level]
Enter this keyword followed by the domain name or domain level.
ma-name name
Enter this keyword followed by the name of the maintenance association.
mepid mep-id
Enter an MEP ID.
Range: 1-8191
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on S-Series
domain [name | level]
Enter this keyword followed by the domain name or domain level.
ma-name name
Enter this keyword followed by the name of the maintenance association.