Reference Guide
1564 | E-Series Debugging and Diagnostics
www.dell.com | support.dell.com
Parameters
Defaults
No default behavior or values
Command Modes
EXEC
EXEC Privilege
Command
History
Example
Figure 65-19. show hardware linecard (E-Series) Command Example
Related
Commands
rpm Enter the keyword rpm to display RPM error counters, status registers, or
packet queue from the BTM.
linecard number Enter the keyword linecard followed by the line card slot number to
display BTM error counters, status registers, or packet queue on the
specified line card.
Range: 0 to 13 on a E1200, 0 to 6 on a E600/E600i, and 0 to 5 on an E300
port-set pipe-number Enter the keyword port-set followed by the number of the line card’s
Port-Pipe.
Range: 0 to 1
egress errors | status |
queues
(OPTIONAL) Enter the keywords egress errors, egress status, or
egress queues to view egress BTM error counters, status registers, or
packet queue.
ingress errors | status |
queues
(OPTIONAL) Enter the keywords ingress errors, ingress status,
or ingress queues to view ingress BTM error counters, status registers,
or packet queue.
all errors | status |
queues
(OPTIONAL) Enter the keywords all errors, all status, or all
queues to view all BTM error counters, status registers, or packet queue
register starting-value
[
number_of_registers]
Enter the keyword register followed by the starting value of the register to
read from.
Range: 0 to 16777212
Optionally, enter the number of registers to read from. If no value is
specified, only one line is displayed.
Range: 1 to 512
Version 6.5.4.0 Introduced
FTOS#show hardware linecard 1 port-set 2 btm all errors
Output for portpipe 0 Ingress
PC_SPI4_BADPORT_CNTR [0x000230] = 16777216
PC_SPI4_EOP_ABORT_CNTR [0x000234] = 33554432
PC_SPI4_MISS_SOP_CNTR [0x00238] = 50331648
Output for portpipe 0 Egress
FC_BAD_CRC_ERR_CNTR [0x000250] = 150994944
FTOS#
clear hardware btm Clear the btm counters