Reference Guide

1556 | E-Series Debugging and Diagnostics
www.dell.com | support.dell.com
Offline Diagnostic Commands
The offline diagnostics test suite is useful for isolating faults and debugging hardware. The tests results
are written to a file in flash memory and can be displayed on screen. Detailed statistics for all tests are
collected.
These statistics include:
last execution time
first test pass time and last test pass time
first test failure time and last test failure time
total run count
total failure count
consecutive failure count
error code
The offline diagnostics commands are:
diag linecard
offline
online
show diag
diag linecard
e
Run offline diagnostics on a line card(s).
Syntax
diag linecard number {alllevels | level0 | level1 | level2} | {terminate}
To terminate the offline diagnostics, use the diag linecard number terminate command.
Parameters
show environment (C-Series
and E-Series)
Display
system component status.
show processes memory
(C-Series and E-Series)
Display memory usage based on running processes.
number
Enter the line card slot number.
Range: 0 to 13 on a E1200, 0 to 6 on a E600, and 0 to 5 on a E300.
alllevels Enter the keyword alllevels to run the complete offline diagnostic test.
level0 Enter the keyword level0 to check the device inventory and verify the
existence of the devices.
level1 Enter the keyword Level1 to verify that the devices are accessible via the
designated paths (line integrity tests) and test the internal registers of the
devices.
level2 Enter the keyword level2 to perform on-board loopback tests on various
data paths (data Port-Pipe and Ethernet).
terminate Enter the keyword terminate to stop the offline diagnostics tests.