Reference Guide
Uplink Failure Detection (UFD) | 1447
debug uplink-state-group
s S50 only
Enable debug messages for events related to a specified uplink-state group or all groups.
Syntax
debug uplink-state-group [group-id]
Parameters
Defaults
None
Command Modes
EXEC Privilege
Command
History
Usage
Information
To turn off debugging event messages, enter the no debug uplink-state-group [group-id] command.
Related
Commands
description
s S50 only
Enter a text description of an uplink-state group.
Syntax
description text
Parameters
Defaults
None
Command Modes
UPLINK-STATE-GROUP
Command
History
Related
Commands
Example
Figure 60-1. description Command Example
group-id Enables debugging on the specified uplink-state group. Valid group-id values
are 1 to 16.
Version 8.4.2.3 Introduced on the S-Series S50.
clear ufd-disable
Re-enable downstream interfaces that are in a UFD-disabled error state.
text
Text description of the uplink-state group.
Maximum length: 80 alphanumeric characters.
Version 8.4.2.3 Introduced on the S-Series S50.
uplink-state-group
Create an uplink-state group and enabling the tracking of upstream
links.
FTOS(conf-uplink-state-group-16)# description test
FTOS(conf-uplink-state-group-16)#