Reference Guide

1404 | S-Series Stacking Commands
www.dell.com | support.dell.com
Example
Figure 56-2. show redundancy Command Output
Related
Commands
show system stack-ports
s
Display information about the stacking ports on all switches in the S-Series stack.
Syntax
show system stack-ports [status | topology]
Parameters
Defaults
No default behavior
FTOS#show redundancy
-- SSeries Redundancy Configuration --
------------------------------------------------
Auto reboot : Enabled
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 7.7.1.0
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 1
Stack-unit SW Version: 7.7.1.0
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Enabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Line Card Config: succeeded Mar 07 1996 00:27:39
Start-up Config: succeeded Mar 07 1996 00:27:39
Runtime Event Log: succeeded Mar 07 1996 00:27:39
Running Config: succeeded Mar 07 1996 00:27:39
ACL Mgr: succeeded Mar 07 1996 00:27:39
redundancy disable-auto-reboot Prevent the system from auto-rebooting if it fails.
status (OPTIONAL) Enter the keyword status to display the command output without the
Connection field.
topology (OPTIONAL) Enter the keyword topology to limit the table to just the Interface and
Connection fields.